Recent Calls

Thu. Sep 2nd 2010
Multiple Alarms For Structure Fire

At this time, Truck 31, Engine 12, Chiefs 80/90/91 with numerous fire departments are on location in the area of River Ridge ...

Read more »


Sat. Aug 14th 2010
Structure Fire at Dollar General

Just after lunch with temperatures over 100 degrees, Truck 31,32 and Engine 11 responded to Dollar General on Hwy 5 for a Bui...

Read more »


Thu. Aug 12th 2010
100+ Temps = Structure Fire

Just after Dinner this evening, Engine 14, Trucks 32, 31 and Battalion Chief 80 responded to Village Green Drive for a Kitche...

Read more »

Upcoming Events
Search Our Site

Search:



Apparatus Gallery
2010 Call Volume
  Fire EMS
January  30  88
February  35  68
March  32  92
April  24  78
May  30  96
June  15  49
July    
August    
September    
October    
November    
December    
Total 166471

View Call Volume History

Links

Arkansas State Fire Prevention Commission


Arkansas Fire News


FEMA




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 | 2 |

Halligan tool (or "Hooligan")
Forcible entry tool with a pointed pick and a wedge at right angles on one end of a shaft and a fork or cat's paw at the opposite end. Used in combination with maul or flat-headed axe for forcing padlocks, doors and windows. Based upon original design by Hugh Halligan of FDNY. Forms the irons" when nested with a flathead axe. Various shaft lengths provide mechanical advantage. Derived from the claw tool (fork and hook).


Halon
Chemical gas fire extinguishing or liquid agent for diminishing the combustion reaction rate by acting as a thermal ballast; used mainly in closed computer rooms, aircraft, and other high-value installations where corrosive chemicals or water extinguishers are judged inappropriate. Effective at low concentrations (5%) as compared with CO2 (34%). Being phased out with suitable replacements in most applications, with very restricted exemptions, due to international environmental concerns with this and other CFCs.


Halyard
Utility rope for raising or lowering moving parts of extension ladder.


Hand crew
A number of individuals that have been organized and trained and are supervised principally for operational assignments on an incident. In the United States, a typical hand crew is 20 in number.


Hard Line
A smaller hose about one inch in diameter used by firefighters to clean apparatus.


Hard suction hose
Non-collapsible sections of hose, usually 10 feet long, used when drafting.


Hazard
A source of danger of personal injury or property damage; fire hazard refers to conditions that may result in fire or explosion, or may increase spread of an accidental fire, or prevent escape from fire. Under worker safety and health regulations, employers have a general duty to provide a workplace free of hazards. See also fire prevention, and HAZMAT.


HAZMAT
Hazardous materials, including solids, liquids, or gasses that may cause injury, death, or damage if released or triggered.


Head of a fire
The most rapidly spreading portion of a fire's perimeter, usually to the leeward or up slope.


Heavy fuels
Fuels of large diameter such as snags, logs, large limb wood, which ignite and are consumed more slowly than flash fuels.


Helispot
A natural or improved takeoff and landing area intended for temporary or occasional helicopter use, typically in remote areas without other access.


Helitack
A fire crew trained to use helicopters for initial attack, and to support large fires through bucket drops and the movement of personnel, equipment and supplies.


Higbee cut (Higby cut'
A tapered thread termination in a firehose coupling for avoiding cross-threading, the location of which is indicated by a notch cut into a single lug on a hose coupling. If the notches are aligned on mating couplings, the Higbee cuts are aligned and the threads will immediately engage when the swivel fitting is turned.


High Pressure Fog (HPF)
A suppression technique consisting of finely atomized water droplets at several hundred pounds per square inch of pressure. By far, one of the most efficient suppression techniques available. Advantages include a *very* high conversion rate, unmatched atmospheric cooling and control of thermal layers, very little wasted water (and consequent water damage), and the ease of managing a small diameter booster line (defined above) during application. Disadvantages are lack of distance, lack of penetration into various materials, and high risk of burns to the attack crew. HPF is quite popular in Europe, but was discarded in the U.S. due to different building construction and the resulting increase in disadvantages.


High-pressure system
A supplemental pump system used to pressurize the water supply, sometimes used during a large fire, or whenever more than one hydrant is being used.


High-rise building
Any building taller than three or four stories, depending upon local usage, requiring firefighters to climb stairs or aerial ladders for access to upper floors.


High-rise pack
A shoulder load of hose with a nozzle and other tools necessary to connect the hose to a standpipe.


High-rise pack
Hose bundle prepared for carrying to a standpipe in a high-rise building, usually consisting of 50 or more feet of 1 3/4-inch hose and a combination nozzle.


Hook
Forged steel hook at end of insulated pole of varying lengths; used for piercing and pulling building materials away from walls and ceilings. Similar to nautical gaff hook. Short hook with a pointed tip is a pike pole; longer hook on a San Francisco hook; two offset hooks on either side of tip is a universal hook; long p-shaped hook is a Boston rake for pulling plaster and lath; short hook with claw on opposite side of tip is either a gypsum hook or the narrower ceiling hook; pike pole with a short handle is a somewhat useless closet hook.


Hose
Flexible conduit for moving liquids under pressure; made of various materials including cotton, rubber or plastic (such as PVC); construction may be braided, woven, wrapped or extruded, often in layers (liner and jacket); hose construction and size differs according to its intended use (e.g., hard suction, attack, forestry, booster); typically stocked in standard lengths and coupled together with standardized fittings. See hose coupling.





Shift Activity

 

Monthly Calls Per Shift
 2010 A B C
Jan      
Feb 35  34  33
Mar  42  39  43
Apr  35  34  34
May  41  46  37
Jun  17  21  26
Jul      
Aug      
Sep      
Oct      
Nov      
Dec      

 

 2009 A B C
Jan  49  45  32
Feb  38  35  41
Mar  41  56  34
Apr  45  39  26
May  48  37  42
Jun  23  47  47
Jul  38  38  38
Aug  42  49  36
Sep  46  39  43
Oct  34  47  39
Nov  39  28  36
Dec  40  58  50

 

 2008 A B C
Jan  27  50  48
Feb  34  38  40
Mar  49  40  51
Apr  47  37  49
May  50  32  41
Jun  41  32  40
Jul 44 43 26
Aug 48 45 36
Sep 46 50 39
Oct 36 31 40
Nov 32 42 30
Dec  40  50  51

 

Yearly Totals
  A B C
2008 494 490 491
2009      

 


Picture Gallery
News Headlines

Tue. Aug 31st 2010
AIR EVAC CRASH

State Police have confirmed that there is a helicopter crash near Scotland in Van Buren County with multiple deaths. At 4:30 ...

Read more »


Tue. Aug 10th 2010
County Wide Burn Ban

Until further notice, the CIty of Bryant and Saline County is under a Burn Ban, until considerate amount of rain oc...

Read more »


Wed. Aug 4th 2010
Arkansas Forestry Commission Line of Duty Death

Arkansas Forestry Commission Ranger Chris Adams was killed Monday morning in a rollover crash while driving a dozer transport...

Read more »

Contact Information

Bryant Fire Department
312 Roya Lane
Bryant, AR  72022

Non-Emergency:
501-847-0483

Emergency:
911

Contact Us
Driving Directions
Map


YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Bryant Fire Department. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Bryant Fire Department.

This site has been
viewed 222,299 times.